Surface Plasmon Resonance (SPR) spectroscopy, a technology developed 25 years ago, is now the gold standard technique for the study of biomolecular interactions for a wide variety of analytes – from small molecules in drug discovery to peptides, proteins, viruses and even nano-particles. SPR is a label-free method capable of measuring real-time quantitative binding affinities, kinetics and thermodynamic parameters of interacting molecules. SPR provides the highest quality data, with moderately high throughput, while consuming relatively small quantities of sample.
The information-rich content of an interaction, which is generated in real-time as well as the high sensitivity and accuracy of this method, make SPR an invaluable tool for biological and pharmaceutical R&D, production and QC. SPR is the only technique from those compared that fulfils the requirements of regulatory authorities (FDA, EMA, ICH).1, 2, 3, 4, 5, 6, 7
With Reichert´s robust and flexible SPR systems it is possible not only to perform standard biomolecular interaction analysis, but also to analyze crude samples and undiluted serum. In addition, Reichert's SPR system can also be used in tandem with liquid chromatography systems and/or mass spectrometers.
As a complement to a robust and flexible instrument hardware that requires little maintenance, XanTec bioanalytics, as the leading manufacturer of biosensor chips, offers the broadest range of sensor chips in the marketplace, meeting virtually every experimental requirement.
ITC is used for quantitative thermodynamic characterization of a wide variety of biomolecular interactions by directly measuring the heat that is either released or absorbed during a biomolecular binding event. ITC is the only technique that can simultaneously determine all thermodynamic binding parameters in a single experiment. This technique requires no modification of binding partners, with fluorescent tags or through immobilization, but it requires, a significantly larger amount of sample compared with similar techniques. ITC measures the affinity of binding partners in their unmodified state, but kinetics (association and dissociation rate constants) cannot be determined with this low-throughput method. [a]
BLI uses white light interferometry to quantify biomolecules which are typically adsorbed to the tips of optical fibers. White light travelling through an optical fiber is reflected at the fiber-biomolecular layer interface and at the biomolecular layer—buffer interface. The reflected beams interfere, generating a signal that directly depends on the amount of adsorbed molecules.
Since the measurement is performed using optical fibers instead of using a fluidic system, it is possible to deliver the sample liquids to the sensor by dipping the optical fibers into well plates. Similar to SPR, immobilization of the ligand is to the surface of the tip is required. BLI provides direct binding affinities and rates of association and dissociation as well as concentration measurements. Due to the very limited temperature control of the samples, a thermodynamic characterization is not possible. Given that only substances bound to the sensor surface are detected, the medium surrounding the sensor does not influence the signal and thus no reference channel is needed c, d.
MST is performed using thin capillaries in free solution, which is comparable to ITC measurements. When performing an MST experiment, a microscopic temperature gradient is induced by an infrared laser, and the directed movement of molecules is detected by intrinsic fluorescence or in most cases, fluorescent labels of one interactant and quantified. The thermophoretic movement of molecules within the temperature gradient depends on size, charge, hydration shell or conformation that typically changes upon interaction. The thermophoresis signal is plotted against the ligand concentration to obtain a dose-response curve, from which the binding affinity can be deduced. The dynamic affinity range covers the pM to mM range, which is comparable to SPR measurements. MST requires a small amount of sample and the technique is relatively easy to use. [b] However, the requirement to use hydrophobic fluorescent labels adds to the overall experimental process and these labels have been known to cause non-specific binding, thus reducing experimental confidence. Additionally, the MST technique cannot provide kinetic information (association and dissociation rates).
A comparison of common techniques for biological interaction analysis reveals that SPR is the most versatile and information-rich analytical method. The tables on the following page further illustrate and highlight the differences between the techniques. The high precision and repeatability of analyte injections compared to MST, BLI and ITC as well as the detailed information about specificity and activity of interacting analytes through the entire analysis and in real time, makes SPR the only accepted method by regulatory authorities. "When ligand binding is part of the functional activity of a biosimilar or therapeutic product, FDA and EMA guidelines require this property be quantified1,2. Binding assays are essential to defining immunological properties and biological activity of monoclonal antibodies3,4,5,6,7." [e]
SPR (Reichert systems) |
ITC | MST | BLI | |
---|---|---|---|---|
Kinetics | Yes | No | No | Yes |
Affinity | Yes | Yes | Yes | Yes |
Thermodynamics | Yes | Yes | Yes | Limited |
Stoichiometry | Yes | Yes | Yes | Yes |
Concentration – analyte | Yes | No | No | Yes |
Affinity range | pM - mM | nM - µM | pM – mM | pM – mM |
Precision of read-out | High | Medium | Low | Medium |
Sensitivity | High | Low | Medium | Low |
Temperature range | 10°C below ambient – 70°C | 2-80°C | 20-45°C | Ambient + 4°C – 40°C |
Sample consumption | Low | High | Very low | Low |
Sample types | Maximum flexibility | Few | Intermediate | Maximum flexibility |
Buffers | No restrictions for aqueous solutions Concentrated Acids/Bases Most organic solvents |
Aqueous solutions with small amounts of organic solvents | No restrictions for aqueous solutions (incl. 8M urea, 4M MgCl2 etc.) | Aqueous solutions with small amounts of organic solvents |
Maintenance | Operator or service technician | Service technician | NA | Service technician |
Signal read-out (change of…) | Refractive index | Temperature | Fluorescence intensity | Wavelength shift |
Benefits | Highest information content Reference method for FDA/ICH/EMA Max experimental flexibility |
No immobilization No labeling |
Low sample consumption | Highest throughput |
Disadvantages | Immobilization of one binding partner required. Trained personnel is required for high quality data |
High sample Consumption Limited applicability – reactions with measureable temperature change. |
Cannot discern 2nd binding site or non-specific binding Labeling with hydrophobic fluorophores required, which can alter binding profile. High CV of fluorescence data. |
Immobilization of one binding partner required. |
SPR (Reichert systems) |
ITC | MST | BLI | |
---|---|---|---|---|
Fragments | √ | √ | ||
Small Molecules | √ | √ | Limited | √ |
Peptides | √ | √ | √ | |
Proteins | √ | √ | √ | √ |
Cell Culture Supernatants | √ | √ | √ | |
Serum | √ | √ | √ | |
Cell Lysates | √ | √ | √ | |
Viruses | √ | √ | ||
Bacteria | √ | √ | ||
Whole Cell Kinetics | √ |